If the MIPI display card has been created, it would create a sysfs debug directory.
 
If the MIPI display card has been created, it would create a sysfs debug directory.
<pre><code>$ ls /sys/class/drm/card0-DSI-1</code>
+
<pre>$ ls /sys/class/drm/card0-DSI-1</code>
 
</pre>
 
</pre>
  
Line 24: Line 24:
  
 
== Check MIPI display card status: status, enabled, modes ==
 
== Check MIPI display card status: status, enabled, modes ==
<pre><code>$ cd /sys/class/drm/card0-DSI-1
+
<pre>$ cd /sys/class/drm/card0-DSI-1
 
$ cat status  # should printed "connected" or "disconnected"
 
$ cat status  # should printed "connected" or "disconnected"
 
$ cat enabled # should printed "enabled" or "disabled"
 
$ cat enabled # should printed "enabled" or "disabled"
$ cat modes  # should printed the available mode list, like 1536x2048</code>
+
$ cat modes  # should printed the available mode list, like 1536x2048
 
</pre>
 
</pre>
  

Latest revision as of 07:37, 11 October 2017

References

source code

device-tree document

 

Tips

Whether MIPI display card has been registered successfully

If the MIPI display card has been created, it would create a sysfs debug directory.

$ ls /sys/class/drm/card0-DSI-1</code>

So you just need to check that directory. If that directory is missing in your machine board, please check:

  • Whether MIPI have been enabled in DTS files.
  • Whether MIPI panel have been registered successfully.
  • Whether you have available VOP module for MIPI.
  • Check the kernel log for more detail (dmesg | grep mipi)

Check MIPI display card status: status, enabled, modes

$ cd /sys/class/drm/card0-DSI-1
$ cat status  # should printed "connected" or "disconnected"
$ cat enabled # should printed "enabled" or "disabled"
$ cat modes   # should printed the available mode list, like 1536x2048

If you still have no picture on MIPI panel, please check bellow information:

  • Check the MIPI panel power supply.
  • Check the panel datasheet, ensure you have configured the timing and power sequence rightly.
  • Check the hardware connected status, or test the panel on workable board.